PA8HF power amplifier
Operating guide
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Operating guide

Meggitt Sensing Systems 20511 Seneca Meadows Parkway, Germantown MD 20876, USA Meggitt (Maryland), Inc d/b/a Meggitt Sensing Systems Tel: +1 (301) 33

Page 2 - Contents

Page 10 of 12 4.0 Operation 4.1 Applying power Verify the AC voltage is correct and all necessary cables are securely attached.

Page 3 - Safety section

Page 11 of 12 5.0 Maintenance WARNING: Lethal voltages are present within the chassis of the power amplifier whenever AC power is

Page 4 - Safety summary

Page 12 of 12 6.0 Technical assistance 6.1 Technical assistance For technical assistance, please contact Meggitt Sensing Systems

Page 5 - 1.1 Front panel

Page 2 of 12 Contents Safety section 3 Safety summary 4 1.0 Product description 5 1.1 Front panel 5

Page 6 - 1.2 Rear Panel

Page 3 of 12 WARNING: OPERATION OF THIS AMPLIFIER IS SAFE WHEN THE INSTRUCTIONS IN THIS MANUAL ARE READ THOROUGHLY BEFORE THIS SYSTE

Page 7

Page 4 of 12 Safety summary 1. Make sure that the power amplifier is properly grounded to a good earth ground. 2. Make sure that

Page 8 - 2.3 Matching networks

Page 5 of 12 1.0 Product description The PA8HF is a single-channel, rack-mountable power amplifier designed to high performance st

Page 9 - 3.2 Signal input

Page 6 of 12 1.2 Rear Panel 1.2.1 Line cord socket: The power amplifier is powered from the AC line using a standard power cord t

Page 10 - 4.2 Test operation

Page 7 of 12 2.0 Operation of the power amplifier Meggitt Sensing Systems manufactures a comprehensive line of vibration generatin

Page 11 - 5.0 Maintenance

Page 8 of 12 networks at frequencies less than 500 Hz. Piezoelectric shakers have little or no useful output at low frequencies. 2.

Page 12 - 6.1 Technical assistance

Page 9 of 12 3.0 Initial system setup Note: All cables should be installed and connections should be completed before switching t